Skip to main content
Premier resource for practicing structural engineers
Go back to https://www.structuremag.org/articles Back
Steel

Opportunities for Castellated Steel in Framing Solutions

By Brandon Bell and Jack Koehler, PE, SE
November 2, 2026

To view the figures and tables associated with this article, please refer to the flipbook above.

Sometimes looking to the past gives you the best route forward. In the world of structural engineering, an innovative workaround originally developed during World War II steel shortages has stepped back into the spotlight to redefine modern commercial construction: castellated steel beams.

In recent years, supply chain disruptions across the structural steel industry—driven by unprecedented warehouse and data center construction—forced commercial project schedules to adapt. When traditional bar joist lead times extended past 12 months and marketplace volatility surged, structural engineers and fabricators deployed alternative framing solutions to maintain project momentum.

However, what began as a temporary supply-crunch strategy has revealed permanent, compounding structural efficiencies across high-bay industrial footprints, retail anchors, multi-story Class-A commercial environments, steel and mass timber hybrid structures, and multi-level parking facilities.

By combining modern 3D CNC automated plasma laser cutting with advanced robotic welding infrastructure, castellated steel beam framing solutions have evolved into a highly standardized, cost-competitive alternative to traditional open-web steel joists and cast-in-place concrete systems.

Manufacturing and Material Mechanics

The core engineering advantage of a castellated beam lies in its geometric transformation. The manufacturing process begins with a standard hot-rolled wide-flange section (W-shape). An automated plasma cutter executes a continuous, mathematically optimized profile cut along the longitudinal axis of the web. The two resulting structural halves are separated, shifted by half a geometric pitch to align the high points of the cut, and re-welded at the web posts.

This structural expansion increases the overall depth of the member by 1.4 to 1.7 times the root wide-flange depth (approximately a 50% increase in total depth), creating a series of repeating hexagonal web voids.

Geometric & Structural Section Properties

From a structural mechanics standpoint, this depth expansion yields a dramatic, non-linear increase in the member’s strong-axis properties:

  • Moment of Inertia: Increases by 120% to 150% (2.2x to 2.5x the baseline section).
  • Section Modulus: Increases by 40% to 70% (1.4x to 1.7x the baseline section).
  • Member Weight: Achieves 0% net weight increase (zero additional raw steel tonnage).

The structural engineer effectively captures deep-beam bending capacities and long-span deflection control while maintaining the lightweight material profile of a much shallower section.

Tailoring Geometry for Specialized Demands

While standard symmetric expansion satisfies most uniform gravity loading conditions, structural engineers can further refine section properties when floor plates demand non-uniform stress distribution.

Asymmetric Member Profiles

In advanced floor framing applications subject to composite action or uneven top/bottom flange stress ratios, castellated beams can be manufactured asymmetrically (e.g., pairing a lighter top W-section half with a heavier bottom W-section half). This optimizes steel distribution precisely where flexural demand requires it.

Quantitative Industrial Roof Framing Comparison

While open-web bar joists have long been the default choice for single-story industrial roofs due to their efficiency in long-span applications, a side-by-side technical evaluation demonstrates why castellated beams offer a superior structural profile across the total building envelope (Table 1).

Systemic Efficiencies: The Tilt-Panel “Snowball Effect”

In concrete tilt-up or perimeter masonry structures, shortening the exterior building envelope by compressing roof framing depth triggers three compounding structural benefits:

  1. Reduced Lateral Forces: Lowering total building height decreases the surface area exposed to wind loads, lowering base shear and lateral design forces.
  2. Reduced Reinforcing Steel: Shortening the unbraced wall height lowers the secondary bending moments on exterior concrete tilt panels, reducing the volume of rebar required for panel stabilization.
  3. Foundation Savings: Lighter structural dead loads and reduced wall panel thickness decrease footing dimensions, slashing the total cubic yardage of concrete required across foundations.

Engineering Workflow: Eliminating Submittal Bottlenecks

While compressing the physical building envelope delivers clear structural savings, substituting castellated profiles for traditional steel joists also eliminates critical schedule friction in the engineering office.

Traditional open-web joist configurations rely heavily on proprietary manufacturer designs, almost universally requiring a deferred submittal process. Under standard joist specifications, the Structural Engineer of Record (EOR) defines loading criteria and spacing layouts, but secondary engineering, web configuration, and component-level calculations are handed off to the specialty joist manufacturer.

This handoff introduces significant project schedule risk. The project team must wait for independent manufacturer engineering turnarounds, route calculations back through the EOR for secondary review, and submit packages to local municipal jurisdictions for plan check approval.

Because section properties, web post boundary conditions, and detailing mechanics of castellated beams follow standardized AISC steel design criteria (such as AISC Design Guide 31), the EOR can analyze and finalize the in-place condition upfront and bypass the deferred submittal loop entirely. The entire framing network can be modeled in primary 3D structural analysis software and incorporated directly into the initial municipal building permit package, compressing the engineering timeline. This upfront clarity also streamlines tenant improvements or mid-construction scope adjustments. Because the EOR retains complete 3D structural calculations from day one, design revisions can be incorporated immediately without waiting for third-party manufacturer recalculations.

Expanding Beyond Standard Floor Plates

The schedule, material, and spatial advantages of castellated framing are not limited to single-story warehouses or Class-A commercial towers. As structural engineers search for lightweight, long-span alternatives to heavy concrete framing, expanded steel beams are increasingly taking on specialized structural typologies with demanding clearance requirements—most notably, mission-critical data centers and multi-level parking facilities.

Specialized Applications

Data Center Roof Framing

Data center construction presents a demanding structural combination: wide-span roof requirements coupled with exceptionally heavy, dynamic MEP equipment loads. Data center designers frequently avoid traditional open-web joists because suspended cable trays, liquid-cooling piping, and heavy electrical distribution drop-downs impose localized bottom-flange point loads that are unpredictable at the time of initial structural design. In double-angle joist chords, concentrated point loads placed off-panel can induce severe local bending stresses and buckling failures.

Castellated beams solve this by delivering long-span bending rigidity and heavy load capacity without adding raw tonnage. Derived from solid rolled wide-flange shapes, the continuous bottom “T” flange provides substantial local flexural and shear resistance. This gives engineers and facility operators the flexibility to attach heavy suspended utility runs and point loads anywhere along the bottom flange or through web posts without requiring custom field-reinforcing or restrictive load-point layouts.

Multi-Level Parking Structures

While precast concrete and cast-in-place (CIP) post-tensioned systems have historically dominated multi-level parking garage design, structural steel utilizing castellated framing has emerged as a high-performance alternative. When comparing baseline framing options for a standard 61 feet parking bay module, castellated steel provides comparable structural depths while offering spatial, architectural, and passive safety advantages over traditional concrete systems (Table 2).

Hybrid Applications: Mass Timber & Floor Assemblies

To create commercial interiors with low embodied carbon profiles, structural designers are increasingly pairing asymmetric or standard wide-flange castellated beams with mass timber paneling.

In this hybrid floor assembly, 5-ply cross-laminated timber (CLT) or plywood panels rest directly on the top flange of the castellated beam and are anchored using self-tapping structural wood screws installed directly through the steel flange.

A typical high-performance acoustic and fire floor stack-up features a 2- inch Gypcrete topping poured over a 1-inch acoustic mat supported by the 5-ply wood deck (yielding a total wood and topping floor thickness of approximately 6 7/8 inches resting atop the expanded steel members.
By eliminating solid steel or concrete webs, the open hexagonal voids of the underlying castellated beams provide built-in MEP pathways directly beneath the timber ceiling.

This versatile hybrid integration expands castellated beam applications beyond industrial roofs into modern office, commercial, healthcare, recreation, public, and institutional facilities.

Case Study: Sprouts Corporate Campus & Flagship Store

The Sprouts Farmers Market Corporate Campus in Phoenix, Arizona, illustrates the versatility of expanded beams in high-density, multi-use commercial developments. Delivered via a design-build collaboration involving Wespac Construction, Trammell Crow Company, RSP Architects, and PK Associates, the 7-acre campus comprises two distinct building types:

  • Corporate Headquarters: A four-story, 144,500 square feet Class-A commercial office tower utilizing exposed castellated steel profiles as a primary interior architectural feature.
  • Flagship Retail Anchor: An adjoining 25,000 square feet retail supermarket—the first in the region to deploy an open-web castellated roof structure.

Routing main HVAC ductwork directly through the hexagonal web voids preserved more than a foot of clear ceiling height, allowing the design team to maintain an open-concept industrial aesthetic without raising the building’s exterior elevation or violating municipal height limits.

EOR Detailing & Construction Considerations

When finalizing structural specifications and connection details for castellated framing, the Engineer of Record (EOR) must incorporate several critical detailing parameters:

Span Thresholds & Bracing (≥ 40 feet): Mandatory diagonal midspan bracing must be specified for members 40 feet or longer. Specifying field-bolted braces ensures proper erection sequencing during framing. Additional lateral bracing should be evaluated along extended spans to mitigate fabrication sweep.

Beam Splices (Spans > 60 feet): Transport limitations typically require shop or field splices for members exceeding 60 feet. Because bolt holes drilled into flanges reduce effective cross-sectional properties, splice plate locations must be shifted away from areas of peak flexural moment.

End Connection Flexibility: Long-span bearing connections must be detailed to accommodate longitudinal thermal movement as well as end-rotation under live-load deflections.

Wind Uplift & Bottom Flange Stability: The unbraced length of the bottom flange must be evaluated for net wind uplift using realistic dead-load assumptions, adding discrete flange bracing where required.

Girder Web Doublers & Torsional Roll: Web capacity must be verified at girders supporting heavy beam reactions or framing continuously over columns, specifying web doubler plates across multiple openings where necessary. Additionally, perimeter girders receiving long-span composite beams from one side must be evaluated for torsional roll during deck placement.

Camber Management: While camber is easily induced during shop fabrication, long-span roof members must not be over-cambered. Excessive upward deflection near column connections can create low points along column lines, leading to water ponding.

Composite Deck Detailing: Headed shear studs must be detailed to align directly with solid web posts. For composite beams utilizing asymmetric or smaller top T-sections, the unbonded steel member must be checked independently for wet concrete construction loads prior to full composite action.

Summary Technical Checklist for the EOR

When evaluating a potential framing substitution from traditional open-web joists or precast concrete to castellated steel profiles, structural engineering teams should monitor the following parameters:

Span-to-Depth Optimization: Target spans ranging from 36 feet to 70 feet (or up to 100+ feet where strong-axis bending and deflection criteria govern).

Web Void Mapping: Coordinate early with MEP consultants to map maximum duct diameters against the inner inscribed circle of the beam’s hexagonal voids.

Upfront 3D Modeling: Fully model standardized castellated section properties directly in primary structural software to eliminate deferred submittals during municipal plan check.

Vierendeel & Shear Checks: Evaluate secondary Vierendeel bending moments (MV = V x e/2) and check web posts for crippling in high shear regions near supports or concentrated loads.
Holistic Cost Evaluation: Calculate total structural savings across the building envelope, accounting for reduced concrete tilt-panel volumes, lighter foundation footings, and shortened MEP hanger runs. ■

About the Authors

Brandon Bell is the Founder and CEO of Next Level Steel (Mesa and Goodyear, AZ), an employee-owned structural steel fabrication and erection firm specializing in advanced castellated beam manufacturing.

Jack Koehler, PE, SE, is a Co-Founder and Senior Structural Engineer at PK Associates (Scottsdale, AZ), specializing in commercial, industrial, and multi-story structural steel design.