To view the figures and tables associated with this article, please refer to the flipbook above.
The Equivalent Lateral Force (ELF) procedure is the most prevalent method practicing engineers use to analyze flexible diaphragm buildings for seismic forces. Inherent in the ELF formulation is an important assumption: all the vertical elements of the lateral-force-resisting system are continuous to the highest diaphragm in the structure. Many common structures violate this assumption, such as low-rise buildings with stepped roofs, and engineers risk substantially underestimating lateral forces in some elements when using the ELF procedure.
ELF Shortcomings
The ELF procedure approximates the dynamic behavior of multistory buildings by applying an assumed vertical distribution of seismic force up the height of the structure. Using this distribution, proportionally larger forces are applied at the highest floors and smaller forces at the lower floors (ASCE 7-22 Minimum Design Loads and Associated Criteria for Buildings and Other Structures Equations 12.8-12 and 12.8-13). This is generally conservative for vertical elements of the lateral force resisting system, referred to herein as vertical elements, as it maximizes the shear and overturning in the vertical elements at each level. This distribution may underestimate diaphragm forces at lower levels, which is addressed by factors provided in ASCE 7-22 Section 12.10.1.
The ELF procedure is most reliable when applied to buildings with floors that are stacked vertically with relatively consistent footprints. Its use on these types of structures has been studied extensively, and engineers generally regard the resulting force distribution as sufficiently conservative for design.
This conservatism is undermined in buildings with substantially different floor footprints at some levels. A simple case is presented in the first row of Figure 1: a warehouse building with two bays of differing height and flexible diaphragms. If this building is analyzed as a two-story structure using ELF, the following process occurs:
- Seismic weight at each story is calculated.
- Seismic force coefficients are determined using ELF. Proportionally more of the seismic force is applied to the upper diaphragm compared to the lower diaphragm.
- Force is distributed to the supporting vertical elements based on tributary diaphragm area using the flexible diaphragm assumption.
The exterior wall supporting the lower diaphragm (Wall C in Figure 1), is subjected to force only from the lower diaphragm. Per the ELF, this story has a smaller seismic force coefficient and is subjected to less force than if the building’s two diaphragms were at the same elevation. Unlike in a structure with two vertically stacked floors, the seismic force that was distributed to the upper story has no pathway to return to Wall C. Herein lies the potential unconservatism.
The ELF formulation assumes that the vertical elements serve to sufficiently interconnect floor levels to create dynamic interaction between them under seismic loads. When using flexible diaphragms, the engineer assumes a lack of dynamic interaction between adjacent wall lines under seismic loads, as evidenced by the distribution of load based on tributary diaphragm area rather than relative stiffness of the vertical elements. For seismic mass from portions of diaphragms near Wall C to interact dynamically with the upper diaphragm, it must propagate across the lower diaphragm to Wall B, apparently violating the flexible diaphragm assumption.
Alternate ELF Procedures
Given the potential shortcomings of the traditional ELF, or Whole Building ELF, it is prudent to explore potential refinements. Two alternative procedures, each using the traditional ELF applied to subsections of the structure individually, are Diaphragm ELF and Wall Line ELF. Neither of these procedures is currently included in ASCE 7. The first column of Figure 1 illustrates the core assumptions for each procedure.
Diaphragm ELF: Each diaphragm is analyzed as an individual single-story “building” with its surrounding shear walls. Vertical elements that connect to multiple diaphragms are included in both “buildings,” with their design forces taken as the sum of the demands contributed by each diaphragm they attach to. This procedure expands on the idea that the dynamic response of many flexible diaphragm buildings may be dominated by diaphragm deformations rather than vertical element deformations. As such, the procedure neglects the potential dynamic interaction between separate diaphragms.
Wall Line ELF: Each wall line and its tributary diaphragm sections are analyzed as an individual “building.” Forces are distributed vertically to the diaphragm segments using ELF force coefficients. This procedure expands on the core assumptions of flexible diaphragms outlined in ASCE 7—seismic mass distributes to vertical elements based on tributary area, rather than relative stiffness and there is negligible dynamic interaction between separate lines of vertical elements. Notably, this procedure yields the same results as the Whole Building ELF when applied to regular structures with flexible diaphragms.
Comparison of ELF Procedures
Figure 1 illustrates wall and diaphragm in-plane forces for a sample split-level diaphragm building. The building has three wall lines supporting two diaphragms. Wall B is connected to both the high and low diaphragms. The diaphragms each weigh 2 units (nondimensional). Wall mass is ignored for simplicity in this example. All analyzed structures are assumed to be subjected to the same spectral acceleration, where the total base shear V=8. The upper diaphragm is 3 units above grade, and the lower diaphragm is 1 unit above grade. K is assumed to be 1.0 in ASCE 7 Equation 12.8-13, so 75% of the base shear is applied at the upper diaphragm and 25% at the lower diaphragm for the whole-building ELF and Wall B of the wall line ELF. Note that the diaphragm forces presented in Figure 1 are amplified per ASCE 7 Section 12.10.1, where applicable—denoted with an asterisk in the figure.
Several notable similarities and differences are present among procedures:
- The Whole Building ELF assigns the seismic force unequally to Walls A and C, with wall A receiving three times the seismic load of wall C. The Diaphragm ELF and Wall Line ELF assign the load equally to Walls A and C. See note “R” in Figure 1.
- The Diaphragm ELF estimates less seismic force in the upper diaphragm and in the upper half of Wall B relative to the other analysis procedures. See notes “S” and “T” in Figure 1.
- The Wall Line ELF estimates that the seismic force in the upper diaphragm is asymmetric, with larger shear forces near Wall B than Wall A. See note “U” in Figure 1.
- All three procedures provide the same estimate for the force in the low diaphragm and the lower level of Wall B.
Modeling Study
A 3D linear dynamic analysis conducted in ETABS compared the results of the presented ELF procedures. This model was representative of a school gymnasium with surrounding support facilities. A 25-foot central gymnasium space is bordered by three adjoining spaces with low roofs—a 14-foot cafeteria to the north, a 11-foot locker room to the west, and a 11-foot storage area to the south. For simplicity, all diaphragms were assumed to have the same unit weight, the design spectral acceleration was assumed to be equal for all building periods, and walls and diaphragms were light frame wood construction. These simplifications minimize the number of variables to be interpreted in the model results.
The modeled structural elements were limited to wood diaphragms and wood shear walls and modeled as linear elastic thin shells. The shear stiffnesses of diaphragms and shear walls were individually calibrated to match the values provided by AWC Special Design Provisions for Wind and Seismic, 2015 Edition, Equations 4.3-1 and 4.2-1.
Figure 2 shows a representation of the 3D model in both plan and elevation. Note that the wall labels in Elevation X-X of Figure 2 correspond to the theoretical building presented in Figure 1. Wall A is the exterior wall supporting the high diaphragm. Wall B supports both the upper and lower diaphragms. Wall C is the exterior wall supporting the lower diaphragm.
The analysis model presented the following modal characteristics:
- Primary structural vibration modes were dominated by individual diaphragm deformation, with minimal mass participation from other diaphragms.
- Structural vibration modes with substantial in-plane wall mass participation included virtually no mass participation from other wall lines.
These results support the flexible diaphragm assumption and demonstrate that the structure is behaving differently from a multi-story structure with stacked diaphragms.
Figure 3 shows the shear in the X-direction walls for each of the three ELF assumptions as a fraction of the corresponding 3D model wall shear. The authors noted the following observations when comparing the relative predictions of the ELF procedures to those of the 3D model. Although not shown in the figure, similar observations were made for the Y-direction walls.
- The Whole Building ELF drastically underestimates the shear in Wall A, while the Diaphragm and Wall Line ELF procedures provide a more accurate estimate. This is the central concern with the Whole Building ELF presented in this article, and the dynamic analysis supports that concern.
- The Diaphragm ELF underestimates the shear in the upper portion of Wall B, but it otherwise provides results consistent with Wall Line ELF.
- Though not visually represented in this article, the shear stresses in the upper diaphragm are slightly asymmetric in the model, with larger forces near the shared wall. This behavior was also identified by the Wall Line ELF as previously noted in Figure 1.
The dynamic analysis itself is not without shortcomings. Any linear elastic model of a seismic system is necessarily approximate. The data presented herein is provided as an additional argument in support of the theories presented in the earlier sections of this article, rather than a definitive statement on the accuracy of the ELF procedures.
Procedure
In practice, the following Wall Line ELF procedure requires minimal additional computation relative to the Whole Building ELF:
- Determine seismic mass of walls and diaphragms (same as Whole Building ELF).
- Assign seismic mass from diaphragms to wall lines using the flexible diaphragm assumption (same as Whole Building ELF).
- Perform an ELF for each wall line, ignoring the rest of the building. Lump mass at each diaphragm supported by that wall line. Note that each wall line has its own natural period. Also, diaphragms may have different shear demands at each wall line even if the diaphragm is symmetric. This is consistent with observations from the modeling study.
- Design diaphragms and walls for the forces determined from the Wall Line ELF (same as a Whole Building ELF).
Conclusions
Engineers should consider the use of the Wall Line ELF in place of the traditional Whole Building ELF in low-rise buildings with flexible diaphragms that have mezzanines, multiple roof heights, or Vertical Elements that do not extend to the highest roof level of the structure.
For atypical structures, the Wall-Line ELF captures behaviors that the full-building ELF misses. The Wall Line ELF is logically consistent with the flexible diaphragm assumption, providing more rational results for atypical diaphragm layouts. The Wall Line ELF has also shown itself to be the most consistent with 3D dynamic analysis.
Engineers must use judgement when analyzing irregular structures for seismic loading, taking care to assess where the selected analysis method may misrepresent the structural behavior. The Wall-Line ELF is one tool to aid engineers in achieving this goal. ■
About the Authors
Dan Sloat, SE, is an Associate with Degenkolb Engineers in Seattle, WA. He also serves in the AISC national committee for Seismic Design.
Chris Neisius, PE, is a Design Engineer with Degenkolb Engineers in Seattle, WA
